Strany 1 - Timer Module

VMB4PD 1 VMB4PD Push Button and Timer Module for Velbus System

Strany 2 - Features

VMB4PD 10Setting the Display and Push Button Backlight The backlight intensity can be set according to your preferences (completely off, completely o

Strany 3

VMB4PD 11 6. Press the configuration button to quit the display menu if the backlight timer has been deactivated. 7. Activate the b

Strany 4 - Rechargeable

VMB4PD 12Setting the Clock You only need to set the clock from one module. All other modules connected in the system will adopt the set time. 1. Ho

Strany 5

VMB4PD 13 6. Confirm by pressing the upper left button. Remarks: The seconds counter starts from 0 when setting the time. Wait for the beginning

Strany 6

VMB4PD 14Activating the Main Clock All modules (with clock function) connected onto the Velbus® system must adopt the same time in order to work prop

Strany 7 - Configuration

VMB4PD 15Addressing Every module connected onto the Velbus® system must have a unique address which can be set via the configuration menu. Make sure

Strany 8

VMB4PD 16Modifying the Labels It is possible to label all commands so as to explain their function. 1. Hold the configuration button pressed for 4

Strany 9 - Setting the Display Contrast

VMB4PD 175. Move the cursor to the left or to the right using the two upper push buttons. Select the character using the two lower push buttons. 6

Strany 10 - Next display menu

VMB4PD 18Setting the Reaction Time All commands have a short reaction time (65ms) by default. This reaction time can be set at 1, 2 or 3 seconds. 1.

Strany 11 - Quit display menu

VMB4PD 195. Press the lower buttons to set a reaction time of 0, 1, 2 or 3 seconds for the displayed command. Press the configuration button to displ

Strany 12 - Setting the hour

VMB4PD 2 Introduction This unique panel will let you control all of the output modules on the Velbus® system. There is no need to remember the functi

Strany 13 - Setting the minutes

VMB4PD 20Setting the User Mode The module can be used as a control panel or as a control panel with timer. The commands can be automated if the timer

Strany 14 - Activating the Main Clock

VMB4PD 21Programming the Timer Programming can only be done if the timer function was selected in the user mode. The commands can be automated via th

Strany 15 - Configuration button

VMB4PD 224. Press the upper right button to display the next program step. 5. Press the lower right button to display

Strany 16 - Modifying the Labels

VMB4PD 237. Press the upper right button to modify the day of the program step. You can choose from the following: Mo Program

Strany 17 - Quit label editor

VMB4PD 2410. Press the lower buttons to add or to remove the displayed command to or from the program step. Following symbols can be displayed: -

Strany 18 - Setting the Reaction Time

VMB4PD 2513. Press the configuration button to display the next program step setting menu. 14. Press the lower buttons to add or to remove the di

Strany 19

VMB4PD 2617. Press the configuration button to return to the general display 18. Press the lower buttons to add or to remove the display

Strany 20

VMB4PD 27Activating and Deactivating the Timer per Command The program will only be executed if the timer function for the command is activated. Deac

Strany 21 - Program menu

VMB4PD 284. Hold the configuration button pressed for 4 seconds to display the configuration menu. 5. Press the lower right bu

Strany 22

VMB4PD 297. Press the configuration button to enter the next timer activation menu. The module exits the timer activation menu if comm

Strany 23

VMB4PD 3Power Supply: Required power voltage: 12 to 18VDC. Consumption: backlight off: 13mA LEDs off / 15mA LEDs on backlight lowly dimmed: 14mA LE

Strany 24

VMB4PD 3011. Press the configuration button to enter the next timer activation menu. The module exits the timer activation menu if com

Strany 25

VMB4PD 31Use The timer function is deactivated by default and can be activated via the configuration menu (see section “Setting the User Mode”). The

Strany 26 - Quit program menu

VMB4PD 32Using the VMBIRTS IR Remote Stick All 8 commands can directly be activated using the IR remote stick. Point the IR remote stick towards the

Strany 27

VMB4PD 33Troubleshooting No display: • The display contrast is too low. Hold the configuration button pressed for 3 seconds to switch the module to t

Strany 28

VMB4PD 34

Strany 29

VMB4PD 35

Strany 30

VMB4PD 4Connection For connection between the modules, use twisted pair cable (ex. EIB 2x2x0.8mm2, UTP 8x0.51mm - CAT5 or other). Use minimum 0.5mm²

Strany 31

VMB4PD 5Termination: If the module is connected at the start or end of a cable on the VELBUS, place the ‘TERM’ jumper. Remove the jumper in all

Strany 32

VMB4PD 6Use The module consists of 4 push buttons with corresponding LED indication and one configuration push button. The label for each push button

Strany 33 - Troubleshooting

VMB4PD 7Configuration When using the module in the Velbus® system for the first time, configure: • contrast • backlight • push button backlight • clo

Strany 34

VMB4PD 8Remarks: • In configuration mode pressing the push buttons will no more be sent through the Velbus®. • All settings will be saved in the modu

Strany 35

VMB4PD 9Setting the Display Contrast 1. Hold the configuration button pressed for 4 seconds to display the configuration menu. 2. Press the uppe