Technical specifications
DC voltage 0.4/4/40/400/600V
basic accuracy ±(1.5% of rdg + 2 digits) / ±(0.8% of rdg + 2 digits) for 0.4V range
/ ±(2.0% of rdg + 2 digits) for 600V range
input impedance 10Mohm
maximum input 600V
AC voltage 0.4/4/40/400/600V TRUE RMS
basic accuracy ±(1.5% of rdg + 8 digits) / ±(1.0% of rdg + 10 digits) for 0.4V
range / ±(2.0% of rdg + 8 digits) for 600V range
input impedance 10Mohm
frequency range 50-60Hz
maximum input 600V
DC current 40/400/1000V
basic accuracy ±(2.8% of rdg + 10 digits) for 40A range / ±(2.8% of rdg + 8 digits)
for 400A range / ±(3.0% of rdg + 8 digits) for 1000A range
AC current 40/400/1000A TRUE RMS
basic accuracy ±(2.8% of rdg + 10 digits) for 40A range / ±(2.8% of rdg + 8 digits)
for 400A range / ±(3.0% of rdg + 8 digits) for 1000A range
resistance 400/4K/40K/400K/4M/40M
basic accuracy ±(1.0% of rdg + 4 digits) for 400ohm range / ±(1.5% of rdg + 2
digits) for 4K~400K range / ±(2.5% of rdg + 5 digits) for 4M range /
±(3.5% of rdg + 10 digits) for 40M range
overload protection 15s max. 250V (all ranges)
capacitance 4n/40n/400n/4µ/40µ/400µF/4mF/40mF
accuracy ±(5.0% of rdg + 30 digits) for 4nF range / ±(5.0% of rdg + 20
digits) for 40nF range / ±(3.0% of rdg + 5 digits) for 400nF~40µF
range / ±(4.0% of rdg + 10 digits) for 400µF range / ±(5.0% of rdg
+ 10 digits) for 4mF~40mF range
frequency 4,000KHz
basic accuracy ±(1.5% of rdg + 2 digits)
overload protection 15s max. 250V (all ranges)
temperature -40°C~1,000°C
basic accuracy ±(2.5% of rdg + 3°C)
maximum display 3999
LCD display size 22 x 35 mm
power supply 1 x 9V battery (incl.)
dimensions 229 x 80 x 49mm
weight (with battery) ±303g
Komentáře k této Příručce